Uniform Medical Policy ManualSection:Medicine
Policy Number:061
Effective Date: 10/24/2010
Original Policy Date:08/24/2010
Last Review Date:02/11/2020
Date Published to Web: 09/22/2010
Subject:
Bioimpedance Devices for Detection and Management of Lymphedema

Description:
_______________________________________________________________________________________

IMPORTANT NOTE:

The purpose of this policy is to provide general information applicable to the administration of health benefits that Horizon Blue Cross Blue Shield of New Jersey and Horizon Healthcare of New Jersey, Inc. (collectively “Horizon BCBSNJ”) insures or administers. If the member’s contract benefits differ from the medical policy, the contract prevails. Although a service, supply or procedure may be medically necessary, it may be subject to limitations and/or exclusions under a member’s benefit plan. If a service, supply or procedure is not covered and the member proceeds to obtain the service, supply or procedure, the member may be responsible for the cost. Decisions regarding treatment and treatment plans are the responsibility of the physician. This policy is not intended to direct the course of clinical care a physician provides to a member, and it does not replace a physician’s independent professional clinical judgment or duty to exercise special knowledge and skill in the treatment of Horizon BCBSNJ members. Horizon BCBSNJ is not responsible for, does not provide, and does not hold itself out as a provider of medical care. The physician remains responsible for the quality and type of health care services provided to a Horizon BCBSNJ member.

Horizon BCBSNJ medical policies do not constitute medical advice, authorization, certification, approval, explanation of benefits, offer of coverage, contract or guarantee of payment.

__________________________________________________________________________________________________________________________

Secondary lymphedema may develop following surgery for breast cancer. Bioimpedance, which uses resistance to electrical current to compare the composition of fluid compartments, could be used as a tool to diagnose lymphedema.

PopulationsInterventionsComparatorsOutcomes
Individuals:
  • With known or suspected lymphedema
Interventions of interest are:
  • Bioimpedance spectroscopy
Comparators of interest are:
  • Volume displacement
  • Circumferential measurement
Relevant outcomes include:
  • Test validity
  • Symptoms
  • Quality of life

BACKGROUND

Lymphedema

Lymphedema is a chronic accumulation of fluid and fibrous tissue that results from the disruption of lymphatic drainage. Secondary lymphedema of the upper extremity may develop following surgery for breast cancer; it has been reported in approximately 25% to 50% of women following mastectomy. Lymphedema can be a disfiguring condition. It results from lymphatic dysfunction or disruption and can be difficult to diagnose and manage accurately. At least one systematic review has found that early detection of secondary lymphedema in breast cancer improves outcomes.1, One challenge is identifying the clinically significant limb swelling through simple noninvasive methods. Many techniques have been used for documenting lymphedema including measuring differences in limb volume (volume displacement) and limb circumference.

The detection of subclinical lymphedema (ie, the early detection of lymphedema before clinical symptoms become apparent) is another area of study. Detection of subclinical lymphedema (referred to as stage 0 lymphedema) is problematic. The subclinical disease may exist for months or years before overt edema is noted. This approach generally involves comparison of preoperative (ie, baseline) with postoperative measurements, because existing differences between upper extremities (like the effects of a dominant extremity) may obscure subtle differences resulting from the initial accumulation of fluid.

Diagnosis

Bioimpedance spectroscopy is based on the theory that the level of opposition to the flow of electric current (impedance) through the body is inversely proportional to the volume of fluid in the tissue. In lymphedema, with the accumulation of excess interstitial fluid, tissue impedance decreases.

Bioimpedance has been proposed as a diagnostic test for this condition. In usual care, lymphedema is recognized clinically or via limb measurements. However, management via bioelectrical impedance spectroscopy has been proposed as a way to implement early treatment of subclinical lymphedema to potentially reduce its severity.

Regulatory Status

Devices that have been cleared for marketing by the U.S. Food and Drug Administration through the 510(k) process to aid in the assessment of lymphedema are summarized in Table 1.

Table 1. Food and Drug Administration-Cleared Bioimpedance Spectroscopy Devices for Lymphedema

YearDeviceManufacturerIndication
2015MoistureMeterDDelfin Technologies (Stamford, CT)To aidinforming a clinical judgment of unilateral lymphedema in women
2007ImpediMed L-Dex™ U400ImpediMed (Carlsbad, CA)To aid clinical assessment of unilateral lymphedema of the arms in women
FDA product code: OBH.

Related Policies

  • Pneumatic Compression Pumps for Treatment of Lymphedema and Venous Ulcers (Policy #013 in the DME Section)
  • End Diastolic Pneumatic Compression Boot as a Treatment of Peripheral Vascular Disease or Lymphedema (Policy #078 in the Treatment Section)

Policy:
(NOTE: For Medicare Advantage, Medicaid and FIDE-SNP, please refer to the Coverage Sections below for coverage guidance.)

Devices using bioimpedance (bioelectrical impedance spectroscopy) are considered investigational for use in the diagnosis, surveillance, or treatment of members with lymphedema, including use in subclinical secondary lymphedema.


Medicare Coverage:
There is no National Coverage Determination (NCD) or Local Coverage Determination (LCD) for jurisdiction JL for this service. Therefore, Medicare Advantage will follow the Horizon BCBSNJ Medical Policy.

Medicaid Coverage:

For members enrolled in Medicaid and NJ FamilyCare plans, Horizon BCBSNJ applies the above medical policy.

FIDE SNP:

For members enrolled in a Fully Integrated Dual Eligible Special Needs Plan (FIDE-SNP): (1) to the extent the service is covered under the Medicare portion of the member’s benefit package, the above Medicare Coverage statement applies; and (2) to the extent the service is not covered under the Medicare portion of the member’s benefit package, the above Medicaid Coverage statement applies.

[RATIONALE: This policy was created in 2010 and has been updated regularly with searches of the MEDLINE database. The most recent literature update was performed through December 6, 2018.

Evidence reviews assess whether a medical test is clinically useful. A useful test provides information to make a clinical management decision that improves the net health outcome. That is, the balance of benefits and harms is better when the test is used to manage the condition than when another test or no test is used to manage the condition.

The first step in assessing a medical test is to formulate the clinical context and purpose of the test. The test must be technically reliable, clinically valid, and clinically useful for that purpose. Evidence reviews assess the evidence on whether a test is clinically valid and clinically useful. Technical reliability is outside the scope of these reviews, and credible information on technical reliability is available from other sources.

Bioimpedance spectroscopy for Lymphedema

Clinical Context and Test Purpose

The purpose of using bioimpedance spectroscopy in patients who have known, or suspected lymphedema, is to inform a diagnosis subclinical lymphedema to initiate treatment sooner than with other diagnostic methods.

The question addressed in this policy is: Does the use of bioimpedance spectroscopy devices detect lymphedema for individuals with known or suspected lymphedema?

The following PICOTS were used to select literature to inform this review.

Patients

The relevant population of interest are individuals with known or suspected lymphedema.

Interventions

The relevant intervention of interest is bioimpedance spectroscopy.

Comparators

The relevant comparators of interest are volume displacement and circumferential measurement.

Outcomes

The general outcomes of interest are test validity, symptoms, and quality of life.

Timing

The time frame for outcomes varies from months to years after the onset of lymphedema symptoms.

Setting

During a physical exam conducted by a physician in an inpatient or outpatient setting.

Simplifying Test Terms

There are three core characteristics for assessing a medical test. Whether imaging, laboratory, or other, all medical tests must be:

·         Technically reliable

·         Clinically valid

·         Clinically useful.

Because different specialties may use different terms for the same concept, we are highlighting the core characteristics. The core characteristics also apply to different uses of tests, such as diagnosis, prognosis, and monitoring treatment.

Diagnostic tests detect the presence or absence of a condition. Surveillance and treatment monitoring are essentially diagnostic tests over a time frame. Surveillance to see whether a condition develops, or progresses is a type of detection. Treatment monitoring is also a type of detection because the purpose is to see if treatment is associated with the disappearance, regression, or progression of the condition.

Prognostic tests predict the risk of developing a condition in the future. Tests to predict response to therapy are also prognostic. Response to therapy is a type of condition and can be either a beneficial response or adverse response. The term predictive test is often used to refer to the response to therapy. To simplify terms, we use prognostic to refer both to predicting a future condition or to predictresponse to therapy.

Technical Reliability

Assessment of technical reliability focuses on specific tests and operators and requires review of unpublished and often proprietary information. Review of specific tests, operators, and unpublished data are outside the scope of this policy and alternative sources exist. This policy focuses on the clinical validity and clinical utility.

Clinically Valid

A test must detect the presence or absence of a condition, the risk of developing a condition in the future, or treatment response (beneficial or adverse).

A technology assessment on the diagnosis and treatment of secondary lymphedema, performed for the Agency for Healthcare Research and Quality (AHRQ), was published in 2010.2, The AHRQ assessment identified eight studies that reported the sensitivity and specificity of tests to diagnose secondary lymphedema. Reviewers notedthere is no true criterion standard to grade severity of lymphedema and that limb volume and circumference are used as de facto criterion standards. Two of the eight selected studies evaluated bioimpedance devices.3,4, Overall, reviewers concluded that, due largely to heterogeneity among studies, the evidence did not permit conclusions on the optimal diagnostic test for detection of secondary lymphedema.

After the AHRQ review, several other studies have evaluated the diagnostic performance of bioimpedance devices for detecting lymphedema. Prospective studies that compared bioelectrical impedance analysis to a reference standard are described next.

A study by Barrio et al (2015) enrolled 223 women with newly diagnosed breast cancer and a plan for unilateral axillary surgery.5, Thirty-seven patients were excluded due to ineligibility or withdrawal, leaving a sample size of 186. Prior to surgery, participants received baseline volumetric measurements with a bioimpedance device (L-Dex) and volume displacement (the reference standard). Patients then had follow-up volumetric measurements every three to six months for three years. At the last follow-up (median, 18.2 months), 152 (82%) patients had no lymphedema, 21 (11%) had an abnormal L-Dex, and no lymphedema by volume displacement, 4 (2%) had an abnormal L-Dex and lymphedema by volume displacement, and 9 (5%) had lymphedema without prior L-Dex abnormality. In an analysis including only patients with at least 6 months of follow-up, L-Dex had a sensitivity of 31% (4/13) and a specificity of 88% (129/147) for predicting subsequent lymphedema development. Also, the correlation between changes in volume displacement and changes in L-Dex results were in the low-to-moderate range at 3 months (r=0.31) and 6 months (r=0.21). However, at the time of lymphedema diagnosis, the L-Dex ratio was abnormal in 12 of 13 patients (diagnostic sensitivity, 92%).

Blaney et al (2015) reported on a prospective study with 126 women with stage I, II, or III unilateral breast cancer.6, A total of 115 women underwent baseline assessment with an L-Dex and circumferential measurement. The circumferential measurement was used as the reference standard, although the authors noted the test is an imperfect criterion standard. Postsurgical follow-up assessments were planned every three months for a year. The number of women completing these assessments was 109 (95%) at 3 months, 89 (77%) at 6 months, 79 (69%) at 9 months, and 71 (62%) at 12 months. Over 12 months, 31 participants were identified as having lymphedema by at least 1 of the assessment methods. Twenty-eight (90%) of 31 were identified by circumferential measurement and 11 (35%) by bioimpedance spectroscopy. There was no statistically significant correlation between bioimpedance analysis and circumferential measurement.

Section Summary: Clinically Valid

A 2010 AHRQ technology assessment identified few studies on bioimpedance analysis for diagnosing lymphedema. A few prospective studies, published after the AHRQ review, found suboptimal correlations between bioimpedance analysis and the reference standard. In the study that reported measures of diagnostic accuracy, bioimpedance analysis had low sensitivity and specificity for predicting lymphedema development.

Clinically Useful

A test is clinically useful if the use of the results informs management decisions that improve the net health outcome of care. The net health outcome can be improved if patients receive correct therapy, or more effective therapy, or avoid unnecessary therapy, or avoid unnecessary testing.

The ideal study design is a randomized controlled trial comparing health outcomes in patients managed with and without the use of bioimpedance devices. No randomized controlled trials were identified. However, a controlled observational study has compared clinical lymphedema rates in patients managed with and without bioimpedance analysis. This study, by Soran et al (2014), involved prospective detection of subclinical lymphedema in 186 women with breast cancer managed with L-Dex or tape measurement of limb circumference.7, Measurements were obtained at baseline and 3- to 6-month intervals for five years. Subclinical lymphedema was defined as an L-Dex value outside the normal range, or that increased at least ten units from baseline. Patients diagnosed with subclinical lymphedema were treated with, eg, short-term physical therapy, compression garments, and received education on exercise and limb elevation. A total of 180 women were included in the analysis. Seventy-two women had both preoperative and postoperative bioimpedance and tape measurements (preoperative group). Forty-four women had preoperative bioimpedance and tape measurements but only had tape measurements postoperatively (control group). The remaining 64 women had postoperative bioimpedance and tape measurements, but no preoperative measurements (no preoperative group). The authors compared the demographic and clinical characteristics of the preoperative and control groups and the preoperative and postoperative groups; they did not identify any statistically significant differences.

In the preoperative group, 28 (36%) of 72 women were diagnosed with subclinical lymphedema and referred for treatment; 2 women progressed to clinical lymphedema. In the control group, 16 women (36%) developed clinical lymphedema during follow-up. Limitations of the study included a lack of an alternative method for detecting subclinical lymphedema in women in the control group so that they could receive treatment early; a lack of randomization to a treatment group; and incomplete data on pre- and postoperative measures of lymphedema except in a subset of the total population.

Laidley et al (2016), in a retrospective cohort study conducted at 2 surgical practices, reported on the feasibility and outcomes for postoperative bioimpedance monitoring in women following axillary lymph node surgery for breast cancer.8, Of 1113 patients, 326 patients who had undergone some form of axillary staging and preoperative and at least 2 postoperative bioimpedance measurements met the study’s eligibility criteria. The cumulative incidence of subclinical breast cancer-related lymphedema was 12.3%.

Section Summary: Clinically Useful

One prospective comparative study has compared rates of clinical lymphedema in women managed with and without bioimpedance analysis. This study had several limitations, including nonrandomized design, lack of blinding, lack of complete data on a substantial proportion of enrolled patients, and lack of a systematic method for diagnosing lymphedema in the control group. The authors reported a significantly lower rate of clinical lymphedema in patients managed with bioimpedance analysis and who received treatment for subclinical lymphedema. An additional retrospective analysis suggested that postoperative bioimpedance monitoring is feasible but provided limited information on its efficacy. Additional studies to confirm these findings are needed, especially randomized controlled trials and trials that include an alternative method for early or subclinical lymphedema detection.

Summary of Evidence

For individuals who have known or suspected lymphedema who receive bioimpedance spectroscopy, the evidence includes several prospective studies on diagnostic accuracy and a controlled observational study evaluating clinical utility. The relevant outcomes are test validity, symptoms, and quality of life. Recent diagnostic accuracy studies have found a poor correlation between bioimpedance analysis and the reference standard (volume displacement or circumferential measurement). There are no randomized controlled trials evaluating the clinical utility of bioimpedance devices in the management of patients with lymphedema or at high-risk of developing lymphedema. The single prospective comparative study found a significantly lower rate of clinical lymphedema in patients managed with bioimpedance devices. Limitations of this study included its retrospective design, lack of randomization or blinding, and lack of a systematic method for detecting early or subclinical lymphedema in the control group. An additional retrospective analysis suggested that postoperative bioimpedance monitoring is feasible but provides limited information about its efficacy. The evidence is insufficient to determine the effects of the technology on health outcomes.

SUPPLEMENTAL INFORMATION

Clinical Input From Physician Specialty Societies and Academic Medical Centers

While the various physician specialty societies and academic medical centers may collaborateand make recommendations during this process, through the provision of appropriate reviewers, input received does not represent an endorsement or position statement by the physician specialty societies or academic medical centers, unless otherwise noted.

In response to requests, input was received from 2 specialty societies and 2 academic medical centers while this policy was under review in 2011. Three of four reviewers agreed that bioimpedance devices are considered investigational for diagnosis, surveillance, and treatment of patients with lymphedema. The fourth reviewer, from an academic medical center, considered the use of the technology a reasonable alternative, especially in situations in which minor lymphedema can have a large impact on a patient. One specialty society supported further research into the effectiveness of this technology and recommended reimbursement in the context of relevant clinical trials.

Practice Guidelines and Position Statements

No relevant guidelines or statements were identified.

U.S. Preventive Services Task Force Recommendations

Not applicable.

Ongoing and Unpublished Clinical Trials

A search of ClinicalTrials.gov in November 2017 did not identify any ongoing or unpublished trials that would likely influence this review.]
________________________________________________________________________________________

Horizon BCBSNJ Medical Policy Development Process:

This Horizon BCBSNJ Medical Policy (the “Medical Policy”) has been developed by Horizon BCBSNJ’s Medical Policy Committee (the “Committee”) consistent with generally accepted standards of medical practice, and reflects Horizon BCBSNJ’s view of the subject health care services, supplies or procedures, and in what circumstances they are deemed to be medically necessary or experimental/ investigational in nature. This Medical Policy also considers whether and to what degree the subject health care services, supplies or procedures are clinically appropriate, in terms of type, frequency, extent, site and duration and if they are considered effective for the illnesses, injuries or diseases discussed. Where relevant, this Medical Policy considers whether the subject health care services, supplies or procedures are being requested primarily for the convenience of the covered person or the health care provider. It may also consider whether the services, supplies or procedures are more costly than an alternative service or sequence of services, supplies or procedures that are at least as likely to produce equivalent therapeutic or diagnostic results as to the diagnosis or treatment of the relevant illness, injury or disease. In reaching its conclusion regarding what it considers to be the generally accepted standards of medical practice, the Committee reviews and considers the following: all credible scientific evidence published in peer-reviewed medical literature generally recognized by the relevant medical community, physician and health care provider specialty society recommendations, the views of physicians and health care providers practicing in relevant clinical areas (including, but not limited to, the prevailing opinion within the appropriate specialty) and any other relevant factor as determined by applicable State and Federal laws and regulations.

___________________________________________________________________________________________________________________________

Index:
Bioimpedance Devices for Detection and Management of Lymphedema
Bioimpedance Devices for Detection of Lymphedema
L-Dex U400
ImpediMed L-Dex

References:
1. Shah C, Arthur DW, Wazer D, et al. The impact of early detection and intervention of breast cancer-related lymphedema: a systematic review. Cancer Med. Jun 2016;5(6):1154-1162. PMID 26993371

2. Oremus M, Walker K, Dayes I, et al. Technology Assessment: Diagnosis and treatment of secondary lymphedema. Rockville, MD: Agency for Healthcare Research and Quality; 2010.

3. Cornish BH, Chapman M, Hirst C, et al. Early diagnosis of lymphedema using multiple frequency bioimpedance. Lymphology. Mar 2001;34(1):2-11. PMID 11307661

4. Hayes S, Janda M, Cornish B, et al. Lymphedema secondary to breast cancer: how choice of measure influences diagnosis, prevalence, and identifiable risk factors. Lymphology. Mar 2008;41(1):18-28. PMID 18581955

5. Barrio AV, Eaton A, Frazier TG. A prospective validation study of bioimpedance with volume displacement in early-stage breast cancer patients at risk for lymphedema. Ann Surg Oncol. Dec 2015;22 Suppl 3:370-375. PMID 26085222

6. Blaney JM, McCollum G, Lorimer J, et al. Prospective surveillance of breast cancer-related lymphoedema in the first-year post-surgery: feasibility and comparison of screening measures. Support Care Cancer. Jun 2015;23(6):1549-1559. PMID 25398360

7. Soran A, Ozmen T, McGuire KP, et al. The importance of detection of subclinical lymphedema for the prevention of breast cancer-related clinical lymphedema after axillary lymph node dissection; a prospective observational study. Lymphat Res Biol. Dec 2014;12(4):289-294. PMID 25495384

8. Laidley A, Anglin B. The impact of L-Dex((R)) Measurements in assessing breast cancer-related lymphedema as part of routine clinical practice. Front Oncol. Sep 2016;6:192. PMID 27656420

Codes:
(The list of codes is not intended to be all-inclusive and is included below for informational purposes only. Inclusion or exclusion of a procedure, diagnosis, drug or device code(s) does not constitute or imply authorization, certification, approval, offer of coverage or guarantee of payment.)

CPT*

    93702
HCPCS

* CPT only copyright 2020 American Medical Association. All rights reserved. CPT is a registered trademark of the American Medical Association.
_________________________________________________________________________________________

Medical policies can be highly technical and are designed for use by the Horizon BCBSNJ professional staff in making coverage determinations. Members referring to this policy should discuss it with their treating physician, and should refer to their specific benefit plan for the terms, conditions, limitations and exclusions of their coverage.

The Horizon BCBSNJ Medical Policy Manual is proprietary. It is to be used only as authorized by Horizon BCBSNJ and its affiliates. The contents of this Medical Policy are not to be copied, reproduced or circulated to other parties without the express written consent of Horizon BCBSNJ. The contents of this Medical Policy may be updated or changed without notice, unless otherwise required by law and/or regulation. However, benefit determinations are made in the context of medical policies existing at the time of the decision and are not subject to later revision as the result of a change in medical policy

____________________________________________________________________________________________________________________________